Company: Egyptian Styrene and Poly Styrene Production Company - E. Styrenes
| Audit Type: initial
Audit Details (filled by Auditor)
HSE
2025-12-17
Dr. Samir Sherif
Clause 8.1
5
ISO 14001:2015
NC-05: Improper Hazardous Waste Classification and Control
During inspection of waste storage areas:
-Hazardous waste containers were not clearly identified or classified.
-No MSDS documentation was available for hazardous waste.
-Fluorescent lamps were observed disposed of inside general waste drums
ISO 14001:2015 – Clause 8.1
Fluorescent lamps were observed disposed of inside general waste drums
implment control in accordance with criteria
Dr. Samir Sherif
2025-12-25
2025-12-25
Filled by Auditee
Fluorescent lamps are isolated in separate drums
waste segrigation not implemented due to lack of awarness
awarness sessions done by HSE manager for proper waste segrigation