Company: Egyptian Styrene and Poly Styrene Production Company - E. Styrenes
| Audit Type: initial
Audit Details (filled by Auditor)
Storage
2025-12-16
Eng. Mohaed Fouad
8.1
7
ISO 45001:2018
NC-07: Lack of Safety Signage and Traffic Segregation
Site inspection of the packaging unit revealed:
Absence of safety and environmental signage.
No floor markings or defined routes separating forklift movement from pedestrian traffic.
while ISO 45001:2018 – Clause 8.1 REQUIRE THAT The organization shall implement operational controls to eliminate hazards and reduce OH&S risks.
No safety track found in storage area , which it identifed in risk register as an adminstration control
REQUIRE THAT The organization shall implement operational controls to eliminate hazards and reduce OH&S risks.
Eng.Mohamed Fouad
2025-12-25
2025-12-25
Filled by Auditee
study the tracks and made it
due to many changes in factory bags locations inside storge and outside , no supervsion regading this issue
review risk assessment and control actions , and implment all required in risk register and put it in check list with HSE supervisor